中文字幕在线乱码日本-亚洲熟女综合色一区二区三区四区-欧美一区二区三区中文字幕-日韩在线观看视频91-国产日韩精品一区二区三区在线-欧美精品日韩在线亚洲另类-国内精品久久久久久一区二区-曰本熟女一区二区三区-成人动漫一二三区在线观看

產品中心

人粒細胞集落刺激因子(GCSF)酶聯(lián)免疫吸附檢測試劑盒
一鍵復制產品信息
ELK1025
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00
96T*5 ¥10200.00

Overview

Product name: Human GCSF(Colony Stimulating Factor 3, Granulocyte) ELISA Kit
Reactivity: Human
Alternative Names: CSF3; G-CSF; Granulocyte Colony Stimulating Factor; Pluripoietin; Filgrastim; Lenograstim
Assay Type: Sandwich
Sensitivity: 5.4 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Hematology;
Uniprot ID: P09919
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GCSF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GCSF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GCSF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GCSF in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.027 1.941
500.00 1.700 1.614
250.00 1.243 1.157
125.00 0.828 0.742
62.50 0.508 0.422
31.25 0.340 0.254
15.63 0.174 0.088
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GCSF and the recovery rates were calculated by comparing the measured value to the expected amount of GCSF in samples.
Matrix Recovery range Average
serum(n=5) 81-97% 89%
EDTA plasma(n=5) 85-99% 92%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GCSF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-102% 82-96% 87-98% 78-92%
EDTA plasma(n=5) 97-105% 86-98% 84-93% 89-102%
Heparin plasma(n=5) 85-94% 87-105% 92-101% 79-90%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉