高敏型人生長調節(jié)致癌基因a(GROa/CXCL1)酶聯(lián)免疫吸附檢測試劑盒
一鍵復制產品信息
ELK1024HS
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00
96T*5 ¥10200.00

Overview

Product name: High Sensitivity Human GROa/CXCL1(Growth Regulated Oncogene Alpha) ELISA Kit
Reactivity: Human
Alternative Names: CXCL1; GRO1; GROa; GRO-A; MGSA-A; NAP3; SCYB1; Chemokine C-X-C-Motif Ligand 1; Melanoma Growth Stimulating Activity Alpha; Fibroblast Secretory Protein; Neutrophil Activating Protein 3
Assay Type: Sandwich
Sensitivity: 1.53 pg/mL
Standard: 100 pg/mL
Detection Range: 1.57-100 pg/mL
Sample Type: Serum, plasma
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;
Uniprot ID: P09341
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GROa/CXCL1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GROa/CXCL1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GROa/CXCL1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GROa/CXCL1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
100.00 2.328 2.233
50.00 1.579 1.484
25.00 1.263 1.168
12.50 0.876 0.781
6.25 0.539 0.444
3.13 0.312 0.217
1.57 0.217 0.122
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GROa/CXCL1 and the recovery rates were calculated by comparing the measured value to the expected amount of GROa/CXCL1 in samples.
Matrix Recovery range Average
serum(n=5) 85-99% 92%
EDTA plasma(n=5) 92-98% 95%
Heparin plasma(n=5) 79-88% 84%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GROa/CXCL1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-103% 88-95% 85-93% 79-87%
EDTA plasma(n=5) 83-94% 89-100% 80-92% 80-92%
Heparin plasma(n=5) 85-99% 84-91% 82-96% 80-93%