中文字幕在线乱码日本-亚洲熟女综合色一区二区三区四区-欧美一区二区三区中文字幕-日韩在线观看视频91-国产日韩精品一区二区三区在线-欧美精品日韩在线亚洲另类-国内精品久久久久久一区二区-曰本熟女一区二区三区-成人动漫一二三区在线观看

產(chǎn)品中心

豬孕酮(PG)酶聯(lián)免疫吸附檢測試劑盒
一鍵復制產(chǎn)品信息
ELK10008
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00
96T*5 ¥11900.00

Overview 文獻(1)

Product name: Pig PG(Progesterone) ELISA Kit
Reactivity: Pig
Alternative Names: P4; Pregn-4-Ene-3,20-Dione
Assay Type: Competitive Inhibition
Sensitivity: 0.49 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 2h
Research Area: Endocrinology;Reproductive science;Hormone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Pig PG. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Pig PG. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Pig PG in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
100.00 0.199
50.00 0.310
25.00 0.575
12.50 0.842
6.25 1.168
3.13 1.578
1.57 1.877
0.00 2.226

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PG and the recovery rates were calculated by comparing the measured value to the expected amount of PG in samples.
Matrix Recovery range Average
serum(n=5) 78-96% 87%
EDTA plasma(n=5) 94-107% 100%
Heparin plasma(n=5) 88-102% 95%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PG and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-101% 88-97% 97-105% 81-93%
EDTA plasma(n=5) 95-101% 88-102% 79-92% 85-96%
Heparin plasma(n=5) 89-102% 88-103% 79-90% 95-102%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉